UC3610Q Features
|
|
• Dual marked with device part number and DSCC
drawing number
• Manufactured and tested on a MIL-PRF-38534
Certified Line
• QML-38534, Class H and K
• Five hermetically sealed package configurations
• Performance guaranteed over full military
temperature range: -55°C to +125°C
• High speed: 10 M Bit/s
• CMR: > 10,000 V/μs typical
• 1500 Vdc withstand test voltage
• 2500 Vdc withstand test voltage for HCPL-565X
• High radiation immunity
• 6N137, HCPL-2601, HCPL-2630/-31 function
compatibility
• Reliability data
• TTL circuit compatibility
These units are single, dual and quad channel, hermetically sealed optocouplers. The products are
capable of operation and storage over the full military temperature range and can be purchased as either standard product or with full MIL-PRF-38534 Class Level H or K testing or from the appropriate DSCC Drawing. All devices are manufactured and tested on a MIL-PRF-38534 certified line and are included in the DSCC Qualified Manufacturers List QML-38534 for Hybrid Microcircuits. Quad channel devices are available by special order in the 16 pin DIP through hole packages.
|
|
UC3610Q Description
|
|
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Storage Temperature TS -65 +150 °C
Operating Temperature TA -55 +125 °C
Case Temperature TC +170 °C
Junction Temperature TJ +175 °C
Lead Solder Temperature 260 for 10 sec °C
Peak Forward Input Current (each channel, ≤1 ms duration) IF(PEAK) 40 mA
Average Input Forward Current (each channel) IF(AVG) 20 mA
Input Power Dissipation (each channel) 35 mW
Reverse Input Voltage (each channel VR 5 V
Supply Voltage (1 minute maximum) VCC 7.0 V
Output Current (each channel) IO 25 mA
Output Voltage (each channel) VO 7* V
Output Power Dissipation (each channel) PO 40 mW
Package Power Dissipation (each channel) PD 200 mW
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.Consult packaging section of databook for thermal limitations and considerations of package.
|