18PA1 Supplier,Distributor,Price,Datasheet,PDF

18PA1 distributor(TERMINAL BLOCK / LIMIT SWITCH),18PA1 short lead time

Part Number:   18PA1
Description:   TERMINAL BLOCK / LIMIT SWITCH
Category:   Switches
Manufacture:   Honeywell Sensing and Control
Package:   18PA1
Standard Package:   Switches
   Send RFQ for 18PA1 

18PA1 Distributor,Datasheet,PDF,Suppliers,Price


关于Instagram广告如何运作:https://www.ikjzd.com/articles/144883
重要!亚马逊突然降低库存限制,但IPI分数又提高了……:https://www.ikjzd.com/articles/144884
东南亚Lazada&Shopee选品的思路和方法分析:https://www.ikjzd.com/articles/144886
拉美电商:揭秘Mercado Libre上的中国卖家生存现状:https://www.ikjzd.com/articles/144887
欧盟ROHS认证办理费用多少钱:https://www.ikjzd.com/articles/144888
近几天 你的产品在亚马逊是不是也搜索不到了?:https://www.ikjzd.com/articles/144895
普吉岛特价旅游-普吉岛旅游自由行:https://www.vstour.cn/a/452308.html
河南云台山自驾旅游攻略(详细介绍云台山的旅游路线和注意事项):https://www.vstour.cn/a/452309.html
1 pcs
Mininum order quantity from 1PCS 18PA1
Mininum order value from 1USD
2 days
lead time of 18PA1 is from 2 to 5 days
12 hours
Fast quotation of 18PA1 within 12 hours
60 days
60 days full quality warranty of 18PA1
 
1, we will give you new and original parts with factory sealed package
2, Quality warranted: All products have to be passed our Quality Control before delivery.
2,If you need more details of 18PA1,like pictures ,package,datasheet and so on, pls email to [email protected]

Switch Contact Ratings
Switch contacts are rated with a maximum voltage and current, and there may be different ratings for AC and DC. The AC values are higher because the current falls to zero many times each second and an arc is less likely to form across the switch contacts.  18PA1 Honeywell Sensing and Control TERMINAL BLOCK / LIMIT SWITCH
For low voltage electronics projects the voltage rating will not matter, but you may need to check the current rating. The maximum current is less for inductive loads (coils and motors) because they cause more sparking at the contacts when switched off. 18PA1 Honeywell Sensing and Control TERMINAL BLOCK / LIMIT SWITCH
 

Switch Contacts
Several terms are used to describe switch contacts: 18PA1 Honeywell Sensing and Control TERMINAL BLOCK / LIMIT SWITCH
Closed - on position, contacts conducting, there may be several on positions.
For example: the simplest on-off switch has one set of contacts (single pole) and one switching position which conducts (single throw). The switch mechanism has two positions: open (off) and closed (on), but it is called 'single throw' because only one position conducts.
Way - number of conducting positions, three or more. 18PA1 Honeywell Sensing and Control TERMINAL BLOCK / LIMIT SWITCH
Momentary - switch returns to its normal position when released.
Open - off position, contacts not conducting. 18PA1 Honeywell Sensing and Control TERMINAL BLOCK / LIMIT SWITCH
Pole - number of switch contact sets. 18PA1 Honeywell Sensing and Control TERMINAL BLOCK / LIMIT SWITCH
Throw - number of conducting positions, single or double.